How Do You Read A METAR And TAF?
A METAR is a coded hourly airport observation: station, time, wind in degrees true and knots, visibility, weather, clouds in hundreds of feet above ground, temperature, dew point and altimeter, then remarks. A TAF forecasts the same items within 5 statute miles of the runway, changing with FM, TEMPO and PROB groups.
Aviation weather looks like a cat walked across a keyboard. It is actually one of the most efficient languages ever written. Once you can read it, a single line tells you more than a whole TV forecast.
Key Takeaways
- METAR and TAF winds are in degrees true; tower and ATIS winds are magnetic.
- The ceiling is the lowest broken, overcast or vertical visibility layer.
- An FM group replaces the forecast; a TEMPO is a real condition to plan around.
- PIREPs are the only direct observations of conditions aloft.
- Read METAR trends and remarks, not only the latest body.
Aviation weather speaks a compressed language built for teletype circuits in the 1940s and standardized internationally by ICAO and the WMO. Three products form its grammar: the METAR tells you what the airport is doing now, the TAF tells you what the forecaster expects the airport to do, and the PIREP tells you what the air between airports actually did to a real airplane. A professional pilot reads all three together, because each covers a weakness of the others.
How Do You Decode A METAR?
Consider this routine report from Orlando International during a summer afternoon:
`METAR KMCO 241953Z 27012G22KT 3SM +TSRA BR BKN015CB OVC040 24/22 A2992 RMK AO2 PK WND 27035/1942 LTG DSNT ALQDS TSB38 SLP132 P0045 T02390222`
- KMCO: ICAO station identifier.
- 241953Z: the 24th day of the month at 1953 UTC. Routine METARs are taken just before the top of the hour; a SPECI is an unscheduled special issued when conditions cross a threshold.
- 27012G22KT: wind from 270 degrees true at 12 kt, gusting 22 kt. (ATIS and tower winds are magnetic; METAR and TAF winds are true.) Variable direction shows as `VRB` or as a range such as `240V300`.
- 3SM: prevailing visibility 3 statute miles.
- +TSRA BR: thunderstorm with heavy rain, plus mist. Intensity prefix (`-`, none, `+`), descriptor (TS, SH, FZ, BL, MI, BC, DR, PR), precipitation (RA, SN, DZ, GR, GS, PL, IC, UP), obscuration (BR, FG, HZ, FU, VA, DU, SA) and other (SQ, FC, PO, SS, DS).
- BKN015CB OVC040: broken cumulonimbus base at 1,500 ft AGL, overcast at 4,000 ft. Heights are hundreds of feet above ground level.
- 24/22: temperature 24 C, dew point 22 C. A 2 C spread warns that any cooling will lower ceilings fast.
- A2992: altimeter setting 29.92 inHg.
The remarks often hold the best information:
- AO2: automated station with a precipitation discriminator.
- PK WND 27035/1942: peak wind from 270 at 35 kt at 1942 UTC, far stronger than the 22 kt gust in the body. That is a convective outflow signal.
- LTG DSNT ALQDS: lightning distant (10 to 30 SM) in all quadrants.
- TSB38: thunderstorm began at 38 minutes past the hour.
- SLP132: sea-level pressure 1013.2 hPa (prefix 10 when the coded value is below 500).
- P0045: 0.45 in of precipitation in the past hour.
- T02390222: the precise temperature and dew point in tenths, 23.9 C and 22.2 C (a leading 1 would indicate negative values).
Ceiling And Flight Category
The Ceiling is the lowest layer reported as broken (BKN), overcast (OVC) or vertical visibility (VV) into an obscuration. FEW and SCT layers never constitute a ceiling. Here the ceiling is 1,500 ft and visibility 3 SM, so the Flight Category is MVFR by ceiling and borderline by visibility:
- VFR: ceiling above 3,000 ft and visibility above 5 SM.
- MVFR: ceiling 1,000 to 3,000 ft and/or visibility 3 to 5 SM.
- IFR: ceiling 500 to below 1,000 ft and/or visibility 1 to below 3 SM.
- LIFR: ceiling below 500 ft and/or visibility below 1 SM.
The worse of the two values sets the category.
What Do FM, TEMPO And PROB Mean In A TAF?
`TAF KMCO 241730Z 2418/2524 09008KT P6SM SCT035 FM242000 25012G25KT 3SM TSRA BKN020CB TEMPO 2420/2423 1SM +TSRA BKN008CB FM250200 VRB03KT P6SM SCT250 FM251400 08009KT P6SM SCT040`
- 241730Z: issued on the 24th at 1730 UTC. 2418/2524: valid from the 24th at 1800 UTC to the 25th at 2400 UTC (a 30-hour TAF for a major hub; most are 24 hours).
- P6SM: visibility greater than 6 SM.
- FM242000: from 2000 UTC on the 24th, conditions change completely and permanently to the group that follows. Everything not restated is replaced.
- TEMPO 2420/2423: temporary fluctuations lasting less than an hour each and covering less than half the period. Here, 1 SM in heavy thunderstorm rain with an 800 ft ceiling. For planning, a TEMPO is not a footnote: it is the condition you may be flying into.
- PROB30 / PROB40: a 30 or 40 percent probability of the condition, used in U.S. TAFs only beyond the first 9 hours.
- BECMG: gradual change over the stated period, common in international TAFs.
A TAF covers only the area within 5 SM of the runway complex. `VCTS` means a thunderstorm in the vicinity, 5 to 10 SM. A TAF tells you nothing about the route between airports; that is what area products and PIREPs are for.
Using The TAF For Alternates
Under 14 CFR 91.169, an IFR alternate is required unless, from one hour before to one hour after the ETA, the destination forecast calls for a ceiling of at least 2,000 ft and visibility of at least 3 SM (the 1-2-3 rule). For the TAF above, an arrival at 2100 UTC falls inside both the FM group (BKN020) and the TEMPO 1 SM. An alternate is clearly required, and the TEMPO also tells you to carry fuel to hold or divert.
How Do You Read A Pilot Report (PIREP)?
Satellites, radars and models infer conditions aloft; a PIREP measures them. Two examples:
`UA /OV ORL270015/TM 2010/FL085/TP C172/SK BKN030-TOP070/TA 12/TB LGT-MOD/RM BUILDING CU W`
`UUA /OV MCO090010/TM 2015/FL030/TP B738/TB SEV/RM LOSS 20KT IAS ON FINAL RWY 36R`
- UA / UUA: routine or urgent. Urgent PIREPs cover severe or extreme turbulence (including CAT), severe icing, hail, volcanic ash, low-level wind shear (airspeed change of 10 kt or more within 2,000 ft of the surface), tornadoes and funnel clouds.
- /OV ORL270015: over the 270 radial of the Orlando VOR at 15 nm.
- /TM 2010: time in UTC. /FL085: altitude in hundreds of feet MSL (UNKN or DURD/DURC for climb and descent).
- /TP C172: aircraft type matters because turbulence intensity is aircraft-dependent: light chop in a Boeing 737 can be moderate in a Cessna 172.
- /SK BKN030-TOP070: broken base 3,000 ft, tops 7,000 ft.
- /TA 12: outside air temperature 12 C. /TB, /IC: turbulence and icing intensity and type.
The urgent report above, a 20 kt airspeed loss on final, is exactly the kind of PIREP that should change every following crew's plan.
Reading The Three Together
- Read the METAR trend over the last three hours, not just the latest. A falling temperature/dew point spread, a pressure jump, and a PK WND remark tell a story.
- Compare the current METAR with the TAF valid now. If observations are already worse than forecast, assume the forecast is behind and plan for the worse case.
- Look for PIREPs along your route and within an hour or two. Weight them by aircraft type and time.
- Cross-check against radar, satellite and advisories (next lesson).
Real-World Case: The Value Of A Timely Report
In the July 2, 1994 accident of USAir Flight 1016 at Charlotte, a DC-9 encountered a microburst during a missed approach in a thunderstorm; 37 people died. The NTSB found that the crew lacked real-time information about the storm's severity and that information available to controllers was not fully passed to the flight. Among the lessons: pilot reports of rain intensity and wind shear, and their prompt relay, are safety-critical. A METAR taken minutes earlier showed only a thunderstorm in the vicinity. The air was already lethal.
Try It Here
Real-World Example: USAir 1016 At Charlotte
On July 2, 1994, a DC-9 met a microburst during a missed approach at Charlotte; 37 people died. Recent observations showed only a thunderstorm in the vicinity, and the NTSB found the crew lacked real-time information on the storm's severity. Timely PIREPs and their relay are safety-critical.
Common Mistakes
- Myth: A FEW or SCT layer can be the ceiling. Fact: Only BKN, OVC or VV layers constitute a ceiling.
- Myth: TEMPO conditions are unlikely and can be ignored. Fact: TEMPO conditions are expected to occur intermittently and must be considered for planning and alternates.
- Myth: No PIREPs means smooth, ice-free air. Fact: It only means nobody reported.
Go Deeper: The Remarks Section
Automated stations add groups such as PK WND, WSHFT, TSB/TSE, PRESRR/PRESFR, SLPnnn and Tsnnnsnnn. SLP132 means 1013.2 hPa; T02390222 gives 23.9 C and 22.2 C. A peak wind far above the body gust is a signature of convective outflow.
Check Yourself
No grades, no sign-in. Pick an answer and see how you did. The app keeps score for you and tracks your progress.
1 In `BKN015CB OVC040`, what is the ceiling?
Show The Answer
1,500 ft AGL The ceiling is the lowest broken, overcast or vertical visibility layer, reported in hundreds of feet above ground level.
2 A TAF reads `FM242000 25012G25KT 3SM TSRA BKN020CB TEMPO 2420/2423 1SM +TSRA BKN008CB`. For an ETA of 2100 UTC, which statement is correct?
Show The Answer
An alternate is required because the forecast within one hour of ETA falls below 2,000 ft and 3 SM The TEMPO calls for 800 ft and 1 SM within the 1-hour window around ETA, failing the 1-2-3 rule of 14 CFR 91.169.
3 What does `T02390222` in a METAR remark mean?
Show The Answer
Temperature 23.9 C and dew point 22.2 C The T group gives temperature and dew point to the tenth of a degree; a leading 1 instead of 0 would mean below zero.
4 Which condition requires a PIREP to be coded as urgent (UUA)?
Show The Answer
A 15 kt airspeed loss on final approach due to wind shear Low-level wind shear causing an airspeed change of 10 kt or more within 2,000 ft of the surface qualifies as urgent.
5 Why does the PK WND remark often matter more than the gust in the body of a convective METAR?
Show The Answer
It captures the strongest outflow gust since the last report, which may far exceed the instantaneous gust at observation time Convective outflow is brief and violent; the peak wind remark preserves it even if the gust has subsided by observation time.
Questions People Ask
Are METAR winds true or magnetic?
True. Winds broadcast by ATIS and the tower are magnetic.
How far does a TAF apply?
Within 5 statute miles of the runway complex. VC means 5 to 10 miles.
What makes a PIREP urgent?
Severe or extreme turbulence, severe icing, hail, volcanic ash, tornadoes or funnel clouds, and low-level wind shear with airspeed changes of 10 kt or more.
Learn More From The Experts
Not an official briefing. Get one before you fly, every time. - Jen — Jen